IP Conflict - CRITICAL ISSUE

Date: 2026-01-21
Status: ⚠️ CRITICAL - TWO CONTAINERS USING SAME IP


IP Conflict: 192.168.11.167

Both Containers Are Running and Active

VMID Host Hostname IP Address Interface MAC Address Status
10233 r630-01 npmplus 192.168.11.167 eth1 (net1) BC:24:11:A8:C1:5D Running
10234 r630-02 npmplus-secondary 192.168.11.167 eth0 (net0) BC:24:11:8D:EC:B7 Running

Critical Discovery

UDM Pro MAC Address Match

UDM Pro shows: bc:24:11:8d:ec:b7 for "NPMplus dot 167"
VMID 10234 MAC: BC:24:11:8D:EC:B7 MATCHES

This means:

  • UDM Pro is seeing VMID 10234 (npmplus-secondary) on r630-02
  • NOT VMID 10233 (npmplus) on r630-01
  • Traffic intended for npmplus may be going to the wrong container!

Impact

Network Routing Conflicts

  1. Both containers claim same IP: 192.168.11.167
  2. Both are running: Both have the IP active
  3. MAC address conflict: UDM Pro sees VMID 10234's MAC
  4. Traffic routing: Traffic may be going to wrong container
  5. Connectivity issues: Explains why NPMplus is inconsistent

Why This Causes Problems

  • ARP table conflicts (which MAC responds?)
  • UDM Pro port forwarding may target wrong container
  • Network traffic split between two containers
  • Service availability unpredictable

Resolution

VMID 10234 (npmplus-secondary) should be reassigned to a different IP.

Recommended IP: 192.168.11.168 (next available)

Steps:

  1. Stop VMID 10234
  2. Change IP from 192.168.11.167 to 192.168.11.168
  3. Restart container
  4. Verify no conflicts

Option 2: Remove VMID 10234 IP

If npmplus-secondary is not needed:

  1. Stop VMID 10234
  2. Remove IP assignment
  3. Keep container for other purposes

Verification After Fix

After reassigning VMID 10234:

# Verify no conflicts
# Check r630-01
pct config 10233 | grep 192.168.11.167

# Check r630-02
pct config 10234 | grep 192.168.11.168

# Verify UDM Pro sees correct MAC
# Should see BC:24:11:A8:C1:5D for 192.168.11.167

Summary

Status: ⚠️ CRITICAL IP CONFLICT

Conflict: Two containers using 192.168.11.167

  • VMID 10233 (npmplus) on r630-01
  • VMID 10234 (npmplus-secondary) on r630-02

UDM Pro is seeing: VMID 10234 (wrong container!)

Action Required: Reassign VMID 10234 to different IP (192.168.11.168)


Next Step: Fix IP conflict by reassigning VMID 10234