Migration Plan: r630-01 Data Pool (72% → target <70%)

Last updated: 2026-02-28

Phase 1 completed (2026-02-28): Migrated 8 CTs from data → thin1 on r630-01. data now 65.8% (was 72%); thin1 50.6% (was 43.5%). Migrated VMIDs: 10233, 10120, 10100, 10101, 10235, 10236, 7804, 8640.

Goal: Reduce r630-01 data pool usage (currently ~65.8%, 280G pool) so it stays below 85% and has headroom. Options: move CTs to r630-01 thin1 (same host) or to r630-02 thin5 (cross-host).


1. Current layout (r630-01)

Pool Size Used% Free (approx) Notes
data 280G 65.8% ~100G After Phase 1 migrations; target <70% met.
thin1 208G 50.6% ~107G Now holds migrated CTs from Phase 1.

CTs on data (by size, VMID = container):

VMID Allocated Role / name (typical) Migration priority
25002505 200G each RPC (alltra etc.) Low (critical RPC); move only if needed.
2101 200G Core RPC Do not move (deploy/admin).
1000, 1001, 1002 100G each Validators Do not move (consensus).
1500, 1501, 1502 100G each Sentries Prefer stay; move only if necessary.
10130, 10150, 10151 50100G Services Good candidates (Phase 2).
8640, 8642 50G each Services Good candidates.
7804 20G Gov/portal Good candidate.
10235, 10236 1020G Small services Good candidates.
10232, 10233 13G Small Easy wins.
10100, 10101 8G each Small Easy wins.
10120 4G Small Easy win.

2. Migration options

Option A: Same host — data → thin1 (r630-01)

  • Pros: No node change; no IP/network change; quick (stop → vzdump → destroy → restore to thin1 → start).
  • Cons: thin1 has ~118G free; cannot move all 200G CTs without exceeding thin1.
  • Best for: Smaller CTs (total ~5080G) to free space on data without touching validators/core RPC.

Option B: Cross host — r630-01 → r630-02 thin5

  • Pros: thin5 is empty (237G); can move one or two large CTs (e.g. 200G each).
  • Cons: Node migration (IP may change unless static); service dependency and DNS/load balancer updates.
  • Best for: One or two 200G RPC CTs (e.g. 2503, 2504, 2505) if you need to free a lot of data in one go.

Phase 1 — Same host (data → thin1)

Goal: Free ~5080G on data (get data from 72% to ~5560%) by moving smaller CTs to thin1.

Candidates (order by size, smaller first for low risk):

  1. 10232 (1G), 10233 (3G), 10120 (4G)
  2. 10100 (8G), 10101 (8G), 10235 (10G)
  3. 10236 (20G), 7804 (20G)
  4. Optionally one of: 8640 (50G), 8642 (50G), or 10130 (50G)

Steps per CT (run on r630-01 or via SSH):

# On r630-01 (192.168.11.11). Replace VMID with actual (e.g. 10232).
VMID=10232
ssh root@192.168.11.11 bash -s << 'EOF'
  set -e
  pct stop $VMID
  vzdump $VMID --storage local --compress gzip --mode stop --remove 0
  BACKUP=$(ls -t /var/lib/vz/dump/vzdump-lxc-$VMID-*.tar.gz | head -1)
  pct destroy $VMID --force
  pct restore $VMID $BACKUP --storage thin1
  rm -f $BACKUP
  pct start $VMID
EOF

Automation: Run for each VMID:

bash scripts/maintenance/migrate-ct-r630-01-data-to-thin1.sh <VMID>   # e.g. 10232
bash scripts/maintenance/migrate-ct-r630-01-data-to-thin1.sh 10232 --dry-run  # preview

Suggested order: 10232, 10233, 10120, 10100, 10101, 10235, 10236, 7804, then 8640 or 8642.


Phase 2 — If data still >70%: move one large CT to r630-02 thin5

Goal: Free ~200G on r630-01 data by migrating one 200G CT to r630-02 and placing it on thin5.

Candidates: 2503, 2504, or 2505 (noncore RPC; confirm which can be moved without breaking dependencies).

Steps:

  1. Confirm the CT can run on r630-02 (network, DNS, NPM proxy, etc.).
  2. Migrate (cross-node):
    pct migrate <VMID> r630-02 --storage thin5
    Or: backup on r630-01, copy backup to r630-02, restore on r630-02 with --storage thin5, then destroy on r630-01.
  3. Update any static IPs, DNS, or proxy config pointing to the old host.
  4. Verify service and re-run audit-proxmox-rpc-storage.sh.

4. Scripts to use / create

Action Script / command
List CTs on data ssh root@192.168.11.11 'lvs -o lv_name,lv_size,pool_lv --noheadings pve | grep " data "'
Same-host migration (data → thin1) New script or inline: vzdumppct destroypct restore --storage thin1pct start
Cross-host migration pct migrate <VMID> r630-02 --storage thin5 (or backup/restore to r630-02).
Verify after bash scripts/audit-proxmox-rpc-storage.sh and pvesm status on both hosts.

5. Checklist before migration

  • Backup or snapshot critical CTs before Phase 1.
  • Run prune on r630-01 data CTs again if not done recently: fix-storage-r630-01-and-thin5.sh.
  • Ensure no critical operations (deploy, consensus) during the migration window.
  • For Phase 2: document which VMID is moved and update DNS/NPM/load balancer.

6. Success criteria

  • Phase 1: r630-01 data pool <70% (ideally 5565%); thin1 still <75%.
  • Phase 2 (if run): r630-01 data <65%; r630-02 thin5 used by migrated CT(s); all services verified.

7. Reference

  • r630-01 data: 280G, 72% used; LVs: 1000, 1001, 1002, 15001502, 2101, 25002505, 10100, 10101, 10120, 10130, 10150, 10151, 10232, 10233, 10235, 10236, 7804, 8640, 8642.
  • r630-01 thin1: 208G, 43.5% used; ~118G free.
  • r630-02 thin5: 237G, 0% used (empty).
  • Storage docs: STORAGE_RECOMMENDATIONS_BY_FILL_RATE.md, PHYSICAL_DRIVES_AND_CONFIG.md.