Some checks failed
Deploy to Phoenix / deploy (push) Has been cancelled
- Marked submodules ai-mcp-pmm-controller, explorer-monorepo, and smom-dbis-138 as dirty to reflect recent changes. - Updated documentation to clarify operator script usage, including dotenv loading and task execution instructions. - Enhanced the README and various index files to provide clearer navigation and task completion guidance. Made-with: Cursor
3.6 KiB
3.6 KiB
Hardware inventory — master reference
Last updated: 2026-03-03
Purpose: Single source of truth for total server, workstation, switching, and gateway hardware.
Servers
| Type | Count | Model / notes | Role |
|---|---|---|---|
| Dell PowerEdge R630 | 13 | 2-socket, ECC, 2.5" bays | Proxmox cluster nodes (r630-01 … r630-13); IP plan 192.168.11.11–23. Currently 2 active (r630-01, r630-02); r630-03/04 documented powered off. See R630_13_NODE_DOD_HA_MASTER_PLAN.md. |
| Dell PowerEdge R750 | 3 | 2U, 2-socket, NVMe/SSD, GPU-capable | GPU/AI tier — assign IPs 192.168.11.24–.26; 2–4 PCIe GPUs per node (e.g. A6000, L40S) for ML/inference. Alternative: 2× XE9680 (16× A100 80GB) for heavy AI/training instead of 3× R750. |
R630 IP plan (13 nodes): 192.168.11.11 – 192.168.11.23 (r630-01 … r630-13).
R750 IP suggestion: 192.168.11.24 – 192.168.11.26 (r750-01, r750-02, r750-03). Document in config/ip-addresses.conf as nodes are brought online.
Workstations
| Type | Count | Model / notes | Role |
|---|---|---|---|
| Dell Precision 7920 | 2 | Tower workstation, multi-GPU capable | Admin, dev, or build workstations; assign IPs in 192.168.11.x (e.g. .30–.31); connect to management LAN and/or 10G if NICs support. |
7920 IP suggestion: 192.168.11.30 – 192.168.11.31 (workstation-01, workstation-02).
Gateways / firewalls / WAN aggregation
| Type | Count | Model / notes | Role |
|---|---|---|---|
| ML110 Gen9 | 1 | Dell PowerEdge ML110 Gen9, 8–12 GbE | OPNsense/pfSense WAN aggregator — between 6–10 Spectrum cable modems (WAN) and redundant UDM Pro gateways (LAN). Multi-WAN load balance/failover. See ML110_OPNSENSE_PFSENSE_WAN_AGGREGATOR.md. Prerequisite: Migrate all Proxmox workloads off ML110 before repurpose. |
| UniFi Dream Machine Pro (UDM Pro) | 2 | UniFi UDM Pro | Primary: 192.168.11.1; second: 192.168.11.2 (HA/failover). WAN uplink from ML110 OPNsense/pfSense. Port forward 76.53.10.36 → NPMplus, etc. |
Switching
| Type | Count | Model | Notes |
|---|---|---|---|
| UniFi XG 10G 16-port | 2 | UniFi Switch XG (10GbE, 16 ports) | 10 Gbps backbone for Proxmox inter-node and Ceph storage; dual-attach for HA. See 13_NODE_NETWORK_AND_CABLING_CHECKLIST.md. |
Use for 13-node cluster:
- Ceph cluster network: Dedicated VLAN or subnet across the 10G switches; connect all 13 R630s (and R750s if in Ceph) for backend traffic.
- Management (1G): UDM Pro(s) and existing 1G LAN; workstations and management IPs on same subnet or VLAN.
- Redundancy: Two XG switches allow dual-attach per node (one link per switch or LACP).
References
- 13-node architecture: 02-architecture/R630_13_NODE_DOD_HA_MASTER_PLAN.md
- Network + cabling checklist: 13_NODE_NETWORK_AND_CABLING_CHECKLIST.md
- Bring-online checklist: 13_NODE_AND_ASSETS_BRING_ONLINE_CHECKLIST.md
- Network master: NETWORK_CONFIGURATION_MASTER.md
- ML110 → OPNsense/pfSense: ML110_OPNSENSE_PFSENSE_WAN_AGGREGATOR.md
- r630-03/04 power-on and fixes: reports/R630_03_04_POWER_ON_ISSUES_AND_FIXES.md