Files
proxmox/docs/11-references/HARDWARE_INVENTORY_MASTER.md
defiQUG dbd517b279 Sync workspace: config, docs, scripts, CI, operator rules, and submodule pointers.
- Update dbis_core, cross-chain-pmm-lps, explorer-monorepo, metamask-integration, pr-workspace/chains
- Omit embedded publish git dirs and empty placeholders from index

Made-with: Cursor
2026-04-12 06:12:20 -07:00

4.2 KiB
Raw Blame History

Hardware inventory — master reference

Last updated: 2026-04-07
Purpose: Single source of truth for total server, workstation, switching, and gateway hardware.
Live cluster + LAN edge: newest reports/status/hardware_and_connected_inventory_*.md (refreshed by scripts/verify/poll-proxmox-cluster-hardware.sh + LAN probes).


Servers

Type Count Model / notes Role
Dell PowerEdge R630 13 2-socket, ECC, 2.5" bays Proxmox cluster nodes (r630-01 … r630-13); IP plan 192.168.11.1123. Live in cluster (2026-04-07): ml110 + r630-01 … r630-04 (five votes, quorum OK). r630-05 … r630-13 not on LAN on last sweep. See R630_13_NODE_DOD_HA_MASTER_PLAN.md.
Dell PowerEdge R750 3 2U, 2-socket, NVMe/SSD, GPU-capable GPU/AI tier — planned IPs 192.168.11.24.26. As of 2026-04-07: .26 is not an R750; it hosts VMID 105 legacy NPM (OpenResty). .24/.25 unused on last ping sweep. Alternative: 2× XE9680 (16× A100 80GB) for heavy AI/training instead of 3× R750.

R630 IP plan (13 nodes): 192.168.11.11 192.168.11.23 (r630-01 … r630-13).
R750 IP suggestion: 192.168.11.24 192.168.11.26 (r750-01, r750-02, r750-03). Document in config/ip-addresses.conf as nodes are brought online.


Workstations

Type Count Model / notes Role
Dell Precision 7920 2 Tower workstation, multi-GPU capable Admin, dev, or build workstations; assign explicit unused IPs in 192.168.11.x when provisioned; connect to management LAN and/or 10G if NICs support.

7920 IP note: Do not assume .30 or .31. .30 is currently spare after Omada retirement, and .31 is assigned to Gitea.


Gateways / firewalls / WAN aggregation

Type Count Model / notes Role
ML110 Gen9 1 Dell PowerEdge ML110 Gen9, 812 GbE OPNsense/pfSense WAN aggregator — between 610 Spectrum cable modems (WAN) and redundant UDM Pro gateways (LAN). Multi-WAN load balance/failover. See ML110_OPNSENSE_PFSENSE_WAN_AGGREGATOR.md. Prerequisite: Migrate all Proxmox workloads off ML110 before repurpose.
UniFi Dream Machine Pro (UDM Pro) 2 UniFi UDM Pro Primary: 192.168.11.1; second: 192.168.11.2 (HA/failover). WAN uplink from ML110 OPNsense/pfSense. Port forward 76.53.10.36 → NPMplus, etc.

Switching

Type Count Model Notes
UniFi XG 10G 16-port 2 UniFi Switch XG (10GbE, 16 ports) 10 Gbps backbone for Proxmox inter-node and Ceph storage; dual-attach for HA. See 13_NODE_NETWORK_AND_CABLING_CHECKLIST.md.

Use for 13-node cluster:

  • Ceph cluster network: Dedicated VLAN or subnet across the 10G switches; connect all 13 R630s (and R750s if in Ceph) for backend traffic.
  • Management (1G): UDM Pro(s) and existing 1G LAN; workstations and management IPs on same subnet or VLAN.
  • Redundancy: Two XG switches allow dual-attach per node (one link per switch or LACP).

References