Comprehensive Infrastructure Review
Last Updated: 2025-12-27
Document Version: 1.0
Status: Active Documentation
Review Scope: All Tunnels, DNS Entries, Nginx Configurations, VMIDs
Executive Summary
This document provides a comprehensive review of:
- ✅ All Cloudflare Tunnels
- ✅ All DNS Entries
- ✅ All Nginx Configurations
- ✅ All VMIDs and Services
- ✅ Recommendations for Optimization
1. Cloudflare Tunnels Review
Active Tunnels
| Tunnel Name | Tunnel ID | Status | Location | Purpose |
|---|---|---|---|---|
explorer.d-bis.org |
b02fe1fe-cb7d-484e-909b-7cc41298ebe8 |
✅ HEALTHY | VMID 102 | Explorer/Blockscout |
rpc-http-pub.d-bis.org |
10ab22da-8ea3-4e2e-a896-27ece2211a05 |
⚠️ DOWN | VMID 102 | RPC Services (needs config) |
mim4u-tunnel |
f8d06879-04f8-44ef-aeda-ce84564a1792 |
✅ HEALTHY | Unknown | Miracles In Motion |
tunnel-ml110 |
ccd7150a-9881-4b8c-a105-9b4ead6e69a2 |
✅ HEALTHY | Unknown | Proxmox Host Access |
tunnel-r630-01 |
4481af8f-b24c-4cd3-bdd5-f562f4c97df4 |
✅ HEALTHY | Unknown | Proxmox Host Access |
tunnel-r630-02 |
0876f12b-64d7-4927-9ab3-94cb6cf48af9 |
✅ HEALTHY | Unknown | Proxmox Host Access |
Current Tunnel Configuration (VMID 102)
Active Tunnel: rpc-http-pub.d-bis.org (Tunnel ID: 10ab22da-8ea3-4e2e-a896-27ece2211a05)
Current Routing (from logs):
rpc-ws-pub.d-bis.org→https://192.168.11.252:443rpc-http-prv.d-bis.org→https://192.168.11.251:443rpc-ws-prv.d-bis.org→https://192.168.11.251:443rpc-http-pub.d-bis.org→https://192.168.11.252:443
⚠️ Issue: Tunnel is routing directly to RPC nodes instead of central Nginx
✅ Recommended Configuration:
- All HTTP endpoints →
http://192.168.11.21:80(Central Nginx) - WebSocket endpoints → Direct to RPC nodes (as configured)
2. DNS Entries Review
Current DNS Records (from d-bis.org zone file)
A Records (Direct IPs)
| Domain | IP Address(es) | Proxy Status | Notes |
|---|---|---|---|
api.d-bis.org |
20.8.47.226 | ❌ Not Proxied | Should use tunnel |
besu.d-bis.org |
20.215.32.42, 70.153.83.83 | ✅ Proxied | DUPLICATE - Remove one |
blockscout.d-bis.org |
20.215.32.42, 70.153.83.83 | ✅ Proxied | DUPLICATE - Remove one |
d-bis.org (root) |
20.215.32.42, 20.215.32.15 | ✅ Proxied | DUPLICATE - Remove one |
docs.d-bis.org |
20.8.47.226 | ❌ Not Proxied | Should use tunnel |
explorer.d-bis.org |
20.215.32.42, 70.153.83.83 | ✅ Proxied | DUPLICATE - Remove one |
grafana.d-bis.org |
20.8.47.226 | ❌ Not Proxied | Should use tunnel |
metrics.d-bis.org |
70.153.83.83 | ❌ Not Proxied | Should use tunnel |
monitoring.d-bis.org |
70.153.83.83 | ✅ Proxied | Should use tunnel |
prometheus.d-bis.org |
20.8.47.226 | ❌ Not Proxied | Should use tunnel |
tessera.d-bis.org |
20.8.47.226 | ❌ Not Proxied | Should use tunnel |
wallet.d-bis.org |
70.153.83.83 | ✅ Proxied | Should use tunnel |
ws.d-bis.org |
20.8.47.226 | ❌ Not Proxied | Should use tunnel |
www.d-bis.org |
20.8.47.226 | ✅ Proxied | Should use tunnel |
CNAME Records (Tunnel-based)
| Domain | Target | Proxy Status | Notes |
|---|---|---|---|
rpc.d-bis.org |
dbis138fdendpoint-cgergbcqb7aca7at.a03.azurefd.net |
✅ Proxied | Azure Front Door |
ipfs.d-bis.org |
ipfs.cloudflare.com |
✅ Proxied | Cloudflare IPFS |
Missing DNS Records (Should Exist)
| Domain | Type | Target | Status |
|---|---|---|---|
rpc-http-pub.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
rpc-ws-pub.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
rpc-http-prv.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
rpc-ws-prv.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
dbis-admin.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
dbis-api.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
dbis-api-2.d-bis.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
mim4u.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
www.mim4u.org |
CNAME | <tunnel-id>.cfargotunnel.com |
❌ Missing |
3. Nginx Configurations Review
Central Nginx (VMID 105 - 192.168.11.21)
Status: ✅ Configured
Configuration: /data/nginx/custom/http.conf
Type: Nginx Proxy Manager (OpenResty)
Configured Services:
- ✅
explorer.d-bis.org→http://192.168.11.140:80 - ✅
rpc-http-pub.d-bis.org→https://192.168.11.252:443 - ✅
rpc-http-prv.d-bis.org→https://192.168.11.251:443 - ✅
dbis-admin.d-bis.org→http://192.168.11.130:80 - ✅
dbis-api.d-bis.org→http://192.168.11.150:3000 - ✅
dbis-api-2.d-bis.org→http://192.168.11.151:3000 - ✅
mim4u.org→http://192.168.11.19:80 - ✅
www.mim4u.org→301 Redirect→mim4u.org
Note: WebSocket endpoints (rpc-ws-*) are NOT in this config (routing directly)
Blockscout Nginx (VMID 5000 - 192.168.11.140)
Status: ✅ Running
Configuration: /etc/nginx/sites-available/blockscout
Purpose: Local Nginx for Blockscout service
Ports:
- Port 80: HTTP (redirects to HTTPS or serves content)
- Port 443: HTTPS (proxies to Blockscout on port 4000)
Miracles In Motion Nginx (VMID 7810 - 192.168.11.19)
Status: ✅ Running
Configuration: /etc/nginx/sites-available/default
Purpose: Web frontend and API proxy
Ports:
- Port 80: HTTP (serves static files, proxies API to 192.168.11.8:3001)
DBIS Frontend Nginx (VMID 10130 - 192.168.11.130)
Status: ✅ Running (assumed)
Purpose: Frontend admin console
RPC Nodes Nginx (VMIDs 2500, 2501, 2502)
Status: ⚠️ Partially Configured
Purpose: SSL termination and local routing
VMID 2500 (192.168.11.250):
- Port 443: HTTPS RPC →
127.0.0.1:8545 - Port 8443: HTTPS WebSocket →
127.0.0.1:8546
VMID 2501 (192.168.11.251):
- Port 443: HTTPS RPC →
127.0.0.1:8545 - Port 443: HTTPS WebSocket →
127.0.0.1:8546(SNI-based)
VMID 2502 (192.168.11.252):
- Port 443: HTTPS RPC →
127.0.0.1:8545 - Port 443: HTTPS WebSocket →
127.0.0.1:8546(SNI-based)
4. VMIDs Review
Infrastructure Services
| VMID | Name | IP | Status | Purpose |
|---|---|---|---|---|
| 100 | proxmox-mail-gateway | 192.168.11.32 | ✅ Running | Mail gateway |
| 101 | proxmox-datacenter-manager | 192.168.11.33 | ✅ Running | Datacenter management |
| 102 | cloudflared | 192.168.11.34 | ✅ Running | Cloudflare tunnel client |
| 103 | omada | 192.168.11.30 | ✅ Running | Network management |
| 104 | gitea | 192.168.11.31 | ✅ Running | Git repository |
| 105 | nginxproxymanager | 192.168.11.26 | ✅ Running | Central Nginx reverse proxy |
| 130 | monitoring-1 | 192.168.11.27 | ✅ Running | Monitoring stack |
Blockchain Services
| VMID | Name | IP | Status | Purpose | Notes |
|---|---|---|---|---|---|
| 5000 | blockscout-1 | 192.168.11.140 | ✅ Running | Blockchain explorer | Has local Nginx |
| 6200 | firefly-1 | 192.168.11.7 | ✅ Running | Hyperledger Firefly | Web3 gateway |
RPC Nodes
| VMID | Name | IP | Status | Purpose | Notes |
|---|---|---|---|---|---|
| 2500 | besu-rpc-1 | 192.168.11.250 | ✅ Running | Core RPC | Located on ml110 (192.168.11.10) |
| 2501 | besu-rpc-2 | 192.168.11.251 | ✅ Running | Permissioned RPC | Located on ml110 (192.168.11.10) |
| 2502 | besu-rpc-3 | 192.168.11.252 | ✅ Running | Public RPC | Located on ml110 (192.168.11.10) |
✅ Status: RPC nodes are running on ml110 (192.168.11.10), not on pve2.
Application Services
| VMID | Name | IP | Status | Purpose |
|---|---|---|---|---|
| 7800 | sankofa-api-1 | 192.168.11.13 | ✅ Running | Sankofa API |
| 7801 | sankofa-portal-1 | 192.168.11.16 | ✅ Running | Sankofa Portal |
| 7802 | sankofa-keycloak-1 | 192.168.11.17 | ✅ Running | Sankofa Keycloak |
| 7810 | mim-web-1 | 192.168.11.19 | ✅ Running | Miracles In Motion Web |
| 7811 | mim-api-1 | 192.168.11.8 | ✅ Running | Miracles In Motion API |
DBIS Core Services
| VMID | Name | IP | Status | Purpose | Notes |
|---|---|---|---|---|---|
| 10100 | dbis-postgres-primary | 192.168.11.100 | ✅ Running | PostgreSQL Primary | Located on ml110 (192.168.11.10) |
| 10101 | dbis-postgres-replica-1 | 192.168.11.101 | ✅ Running | PostgreSQL Replica | Located on ml110 (192.168.11.10) |
| 10120 | dbis-redis | 192.168.11.120 | ✅ Running | Redis Cache | Located on ml110 (192.168.11.10) |
| 10130 | dbis-frontend | 192.168.11.130 | ✅ Running | Frontend Admin | Located on ml110 (192.168.11.10) |
| 10150 | dbis-api-primary | 192.168.11.150 | ✅ Running | API Primary | Located on ml110 (192.168.11.10) |
| 10151 | dbis-api-secondary | 192.168.11.151 | ✅ Running | API Secondary | Located on ml110 (192.168.11.10) |
✅ Status: DBIS Core containers are running on ml110 (192.168.11.10), not on pve2.
5. Critical Issues Identified
🔴 High Priority
-
Tunnel Configuration Mismatch
- Tunnel
rpc-http-pub.d-bis.orgis DOWN - Currently routing directly to RPC nodes instead of central Nginx
- Action: Update Cloudflare dashboard to route HTTP endpoints to
http://192.168.11.21:80
- Tunnel
-
Missing DNS Records
- RPC endpoints (
rpc-http-pub,rpc-ws-pub,rpc-http-prv,rpc-ws-prv) missing CNAME records - DBIS services (
dbis-admin,dbis-api,dbis-api-2) missing CNAME records mim4u.organdwww.mim4u.orgmissing CNAME records- Action: Create CNAME records pointing to tunnel
- RPC endpoints (
-
Duplicate DNS A Records
besu.d-bis.org: 2 A records (20.215.32.42, 70.153.83.83)blockscout.d-bis.org: 2 A records (20.215.32.42, 70.153.83.83)explorer.d-bis.org: 2 A records (20.215.32.42, 70.153.83.83)d-bis.org: 2 A records (20.215.32.42, 20.215.32.15)- Action: Remove duplicate records, keep single authoritative IP
-
RPC Nodes Location
- ✅ VMIDs 2500, 2501, 2502 found on ml110 (192.168.11.10)
- Action: Verify network connectivity from pve2 to ml110
-
DBIS Core Services Location
- ✅ VMIDs 10100-10151 found on ml110 (192.168.11.10)
- Action: Verify network connectivity from pve2 to ml110
🟡 Medium Priority
-
DNS Records Using Direct IPs Instead of Tunnels
- Many services use A records with direct IPs
- Should use CNAME records pointing to tunnel
- Action: Migrate to tunnel-based DNS
-
Inconsistent Proxy Status
- Some records proxied, some not
- Action: Standardize proxy status (proxied for public services)
-
Multiple Nginx Instances
- Central Nginx (105), Blockscout Nginx (5000), MIM Nginx (7810), RPC Nginx (2500-2502)
- Action: Consider consolidating or document purpose of each
🟢 Low Priority
-
Documentation Gaps
- Some VMIDs have incomplete documentation
- Action: Update documentation with current status
-
Service Discovery
- No centralized service registry
- Action: Consider implementing service discovery
6. Recommendations
Immediate Actions (Critical)
-
Fix Tunnel Configuration
# Update Cloudflare dashboard for tunnel: rpc-http-pub.d-bis.org # Route all HTTP endpoints to central Nginx: - explorer.d-bis.org → http://192.168.11.21:80 - rpc-http-pub.d-bis.org → http://192.168.11.21:80 - rpc-http-prv.d-bis.org → http://192.168.11.21:80 - dbis-admin.d-bis.org → http://192.168.11.21:80 - dbis-api.d-bis.org → http://192.168.11.21:80 - dbis-api-2.d-bis.org → http://192.168.11.21:80 - mim4u.org → http://192.168.11.21:80 - www.mim4u.org → http://192.168.11.21:80 -
Create Missing DNS Records
- Create CNAME records for all RPC endpoints
- Create CNAME records for DBIS services
- Create CNAME records for MIM services
- All should point to:
<tunnel-id>.cfargotunnel.com - Enable proxy (orange cloud) for all
-
Remove Duplicate DNS Records
- Remove duplicate A records for
besu.d-bis.org - Remove duplicate A records for
blockscout.d-bis.org - Remove duplicate A records for
explorer.d-bis.org - Remove duplicate A records for
d-bis.org(keep 20.215.32.15)
- Remove duplicate A records for
-
Locate Missing VMIDs
- Find RPC nodes (2500-2502) on other Proxmox hosts
- Verify DBIS Core services (10100-10151) deployment status
Short-term Improvements
-
DNS Migration to Tunnels
- Migrate all A records to CNAME records pointing to tunnels
- Remove direct IP exposure
- Enable proxy for all public services
-
Tunnel Consolidation
- Consider consolidating multiple tunnels into single tunnel
- Use central Nginx for all HTTP routing
- Simplify tunnel management
-
Nginx Architecture Review
- Document purpose of each Nginx instance
- Consider if all are necessary
- Standardize configuration approach
Long-term Optimizations
-
Service Discovery
- Implement centralized service registry
- Automate DNS record creation
- Dynamic service routing
-
Monitoring and Alerting
- Monitor all tunnel health
- Alert on tunnel failures
- Track DNS record changes
-
Documentation
- Maintain up-to-date infrastructure map
- Document all service dependencies
- Create runbooks for common operations
7. Architecture Recommendations
Recommended Architecture
Internet
↓
Cloudflare (DNS + SSL Termination)
↓
Cloudflare Tunnel (VMID 102)
↓
Routing Decision:
├─ HTTP Services → Central Nginx (VMID 105:80) → Internal Services
└─ WebSocket Services → Direct to RPC Nodes (bypass Nginx)
Key Principle:
- HTTP traffic routes through central Nginx for unified management
- WebSocket traffic routes directly to RPC nodes for optimal performance
Benefits
- Single Point of Configuration: All HTTP routing in one place
- Simplified Management: Easy to add/remove services
- Better Security: No direct IP exposure
- Centralized Logging: All traffic logs in one location
- Easier Troubleshooting: Single point to check routing
8. Action Items Checklist
Critical (Do First)
- Update Cloudflare tunnel configuration to route HTTP endpoints to central Nginx
- Create missing DNS CNAME records for all services
- Remove duplicate DNS A records
- Locate and verify RPC nodes (2500-2502) - ✅ Found on ml110
- Verify DBIS Core services deployment status - ✅ Found on ml110
- Verify network connectivity from pve2 (192.168.11.12) to ml110 (192.168.11.10)
Important (Do Next)
- Migrate remaining A records to CNAME (tunnel-based)
- Standardize proxy status across all DNS records
- Document all Nginx instances and their purposes
- Test all endpoints after configuration changes
Nice to Have
- Implement service discovery
- Set up monitoring and alerting
- Create comprehensive infrastructure documentation
- Automate DNS record management
9. DNS Records Migration Plan
Current State (A Records - Direct IPs)
Many services use A records pointing to direct IPs. These should be migrated to CNAME records pointing to Cloudflare tunnels.
Migration Priority
High Priority (Public-facing services):
explorer.d-bis.org→ CNAME to tunnelrpc-http-pub.d-bis.org→ CNAME to tunnelrpc-ws-pub.d-bis.org→ CNAME to tunnelrpc-http-prv.d-bis.org→ CNAME to tunnelrpc-ws-prv.d-bis.org→ CNAME to tunnel
Medium Priority (Internal services):
6. dbis-admin.d-bis.org → CNAME to tunnel
7. dbis-api.d-bis.org → CNAME to tunnel
8. dbis-api-2.d-bis.org → CNAME to tunnel
9. mim4u.org → CNAME to tunnel
10. www.mim4u.org → CNAME to tunnel
Low Priority (Monitoring/internal):
11. grafana.d-bis.org → CNAME to tunnel (if public access needed)
12. prometheus.d-bis.org → CNAME to tunnel (if public access needed)
13. monitoring.d-bis.org → CNAME to tunnel
Migration Steps
For each domain:
- Create CNAME record:
<subdomain>→<tunnel-id>.cfargotunnel.com - Enable proxy (orange cloud)
- Wait for DNS propagation (1-5 minutes)
- Test endpoint accessibility
- Remove old A record (if exists)
10. Testing Plan
After implementing recommendations:
-
Test HTTP Endpoints:
curl https://explorer.d-bis.org/api/v2/stats curl -X POST https://rpc-http-pub.d-bis.org \ -H "Content-Type: application/json" \ -d '{"jsonrpc":"2.0","method":"eth_chainId","params":[],"id":1}' curl https://dbis-admin.d-bis.org curl https://mim4u.org -
Test WebSocket Endpoints:
wscat -c wss://rpc-ws-pub.d-bis.org wscat -c wss://rpc-ws-prv.d-bis.org -
Test Redirects:
curl -I https://www.mim4u.org # Should redirect to mim4u.org -
Verify Tunnel Health:
- Check Cloudflare dashboard for tunnel status
- Verify all tunnels show HEALTHY
- Check tunnel logs for errors
11. Summary of Recommendations
🔴 Critical (Fix Immediately)
-
Update Cloudflare Tunnel Configuration
- Tunnel:
rpc-http-pub.d-bis.org(Tunnel ID:10ab22da-8ea3-4e2e-a896-27ece2211a05) - Action: Route all HTTP endpoints to
http://192.168.11.21:80(central Nginx) - Keep WebSocket endpoints routing directly to RPC nodes
- Tunnel:
-
Create Missing DNS CNAME Records
rpc-http-pub.d-bis.org→ CNAME to tunnelrpc-ws-pub.d-bis.org→ CNAME to tunnelrpc-http-prv.d-bis.org→ CNAME to tunnelrpc-ws-prv.d-bis.org→ CNAME to tunneldbis-admin.d-bis.org→ CNAME to tunneldbis-api.d-bis.org→ CNAME to tunneldbis-api-2.d-bis.org→ CNAME to tunnelmim4u.org→ CNAME to tunnelwww.mim4u.org→ CNAME to tunnel
-
Remove Duplicate DNS A Records
besu.d-bis.org: Remove one IP (keep single authoritative)blockscout.d-bis.org: Remove one IPexplorer.d-bis.org: Remove one IPd-bis.org: Remove 20.215.32.42 (keep 20.215.32.15)
🟡 Important (Fix Soon)
-
Migrate A Records to CNAME (Tunnel-based)
- Convert remaining A records to CNAME records
- Point all to Cloudflare tunnel endpoints
- Enable proxy (orange cloud) for all public services
-
Verify Network Connectivity
- Test connectivity from pve2 (192.168.11.12) to ml110 (192.168.11.10)
- Ensure RPC nodes (2500-2502) are accessible from central Nginx
- Ensure DBIS services (10100-10151) are accessible from central Nginx
🟢 Optimization (Nice to Have)
-
Documentation Updates
- Update all service documentation with current IPs and locations
- Document network topology (pve2 vs ml110)
- Create service dependency map
-
Monitoring Setup
- Monitor all tunnel health
- Alert on tunnel failures
- Track DNS record changes
Related Documentation
Architecture Documents
- NETWORK_ARCHITECTURE.md ⭐⭐⭐ - Complete network architecture
- PHYSICAL_HARDWARE_INVENTORY.md ⭐⭐⭐ - Physical hardware inventory
- ORCHESTRATION_DEPLOYMENT_GUIDE.md ⭐⭐⭐ - Deployment orchestration
- DOMAIN_STRUCTURE.md ⭐⭐ - Domain structure
Network Documents
- ../05-network/CLOUDFLARE_TUNNEL_ROUTING_ARCHITECTURE.md - Cloudflare tunnel routing
- ../05-network/CENTRAL_NGINX_ROUTING_SETUP.md - Central Nginx routing
Configuration Documents
- ../04-configuration/cloudflare/CLOUDFLARE_DNS_TO_CONTAINERS.md - DNS mapping to containers
- ../04-configuration/RPC_DNS_CONFIGURATION.md - RPC DNS configuration
Last Updated: 2025-12-27
Document Version: 1.0
Review Cycle: Quarterly