- Organized 252 files across project - Root directory: 187 → 2 files (98.9% reduction) - Moved configuration guides to docs/04-configuration/ - Moved troubleshooting guides to docs/09-troubleshooting/ - Moved quick start guides to docs/01-getting-started/ - Moved reports to reports/ directory - Archived temporary files - Generated comprehensive reports and documentation - Created maintenance scripts and guides All files organized according to established standards.
4.0 KiB
r630-01 Migration Plan - VMIDs 100-130 and 7800-7811
Date: 2025-01-20
Status: Plan Ready
Issue: Storage capacity limits migration options
Storage Requirements
VMIDs 100-130 (7 containers)
Total: 96 GB
- 100: 10 GB
- 101: 10 GB
- 102: 2 GB
- 103: 8 GB
- 104: 8 GB
- 105: 8 GB
- 130: 50 GB
VMIDs 7800-7811 (5 containers)
Total: 210 GB
- 7800: 50 GB
- 7801: 50 GB
- 7802: 30 GB
- 7810: 50 GB
- 7811: 30 GB
Combined Total
306 GB required
r630-01 Storage Available
| Storage | Type | Available |
|---|---|---|
| thin1 | lvmthin | 208 GB |
| local-lvm | lvmthin | 200 GB |
| local | dir | 536 GB |
| Total | 944 GB |
Migration Challenge
Problem: Direct migration fails because:
- Source VMs use thin1/thin4 storage on r630-02
- These storage names don't exist on r630-01 in the same way
- Proxmox migration requires compatible storage or backup/restore
Solution Options:
- Use backup/restore method
- Migrate to available storage (thin1 + local-lvm)
- Distribute VMs across multiple storage pools
Recommended Migration Plan
Option 1: Migrate VMIDs 100-130 to thin1 (96 GB)
- ✅ Fits in thin1 (208 GB > 96 GB)
- ✅ 112 GB remaining on thin1
Option 2: Migrate VMIDs 7800-7811 to local-lvm (210 GB)
- ✅ Fits in local-lvm (200 GB... wait, 210 GB > 200 GB)
- ⚠️ Requires local-lvm + local or just local
Option 3: Mixed Storage (Recommended)
Phase 1: VMIDs 100-130 → thin1
- Storage: thin1 (208 GB available)
- Required: 96 GB
- Margin: 112 GB
Phase 2: VMIDs 7800-7811 → local storage
- Storage: local (536 GB available) or local-lvm + local
- Required: 210 GB
- Available: 536 GB (directory storage)
Migration Method
Since direct migration fails due to storage name differences, use backup/restore method:
Steps for Each VM
-
Create backup on source node
# On r630-02 vzdump <vmid> --storage local --compress gzip --mode stop -
Restore on target node
# On r630-02 (can restore to remote node) pct restore <vmid> /var/lib/vz/dump/vzdump-lxc-<vmid>-*.tar.gz \ --storage <target-storage> \ --target r630-01 -
Delete from source
pct destroy <vmid>
Storage Distribution Plan
Recommended Distribution
thin1 (208 GB):
- VMIDs 100-130: 96 GB
- Remaining: 112 GB
local-lvm (200 GB) + local (536 GB):
- VMIDs 7800-7811: 210 GB
- Use local storage (536 GB > 210 GB)
Migration Commands
VMIDs 100-130 to thin1
# On r630-02
for vmid in 100 101 102 103 104 105 130; do
# Backup
vzdump $vmid --storage local --compress gzip --mode stop
# Restore to r630-01 with thin1 storage
BACKUP=$(ls -t /var/lib/vz/dump/vzdump-lxc-$vmid-*.tar.gz | head -1)
pct restore $vmid $BACKUP --storage thin1 --target r630-01
# Delete from source
pct destroy $vmid
done
VMIDs 7800-7811 to local storage
# On r630-02
for vmid in 7800 7801 7802 7810 7811; do
# Backup
vzdump $vmid --storage local --compress gzip --mode stop
# Restore to r630-01 with local storage
BACKUP=$(ls -t /var/lib/vz/dump/vzdump-lxc-$vmid-*.tar.gz | head -1)
pct restore $vmid $BACKUP --storage local --target r630-01
# Delete from source
pct destroy $vmid
done
Alternative: Use API Migration
If we can resolve the storage issue, API migration would be faster:
# This currently fails due to storage name mismatch
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
--target r630-01 \
--online 0
Summary
Total Storage Needed: 306 GB
Available on r630-01: 944 GB
Status: ✅ Sufficient storage available
Recommended Approach:
- VMIDs 100-130 → thin1 storage (96 GB)
- VMIDs 7800-7811 → local storage (210 GB)
Migration Method: Backup/Restore (required due to storage name differences)
Last Updated: 2025-01-20
Status: Plan Ready - Backup/Restore Method Required