- Organized 252 files across project - Root directory: 187 → 2 files (98.9% reduction) - Moved configuration guides to docs/04-configuration/ - Moved troubleshooting guides to docs/09-troubleshooting/ - Moved quick start guides to docs/01-getting-started/ - Moved reports to reports/ directory - Archived temporary files - Generated comprehensive reports and documentation - Created maintenance scripts and guides All files organized according to established standards.
2.4 KiB
2.4 KiB
r630-01 Migration Complete - VMIDs 100-130 and 7800-7811
Date: 2025-01-20
Status: ✅ Migration Complete
Method: Direct migration via API after storage configuration fix
Migration Summary
VMs Migrated
VMIDs 100-130 (7 containers) → thin1 storage:
- ✅ 100: proxmox-mail-gateway
- ✅ 101: proxmox-datacenter-manager
- ✅ 102: cloudflared
- ✅ 103: omada
- ✅ 104: gitea
- ✅ 105: nginxproxymanager
- ✅ 130: monitoring-1
VMIDs 7800-7811 (5 containers) → local storage:
- ✅ 7800: sankofa-api-1
- ✅ 7801: sankofa-portal-1
- ✅ 7802: sankofa-keycloak-1
- ✅ 7810: mim-web-1
- ✅ 7811: mim-api-1
Total: 12 containers successfully migrated
Issues Resolved
Storage Configuration Fix
Problem:
- thin1 storage configuration on r630-02 pointed to
nodes r630-01 - thin1 storage showed as disabled on r630-02
- Migration and backup operations failed
Solution:
- Updated storage configuration: Changed
nodes r630-01tonodes r630-02for thin1 - Enabled thin1 storage:
pvesm set thin1 --disable 0 - Migration then succeeded using API method
Migration Method
Direct Migration via API
Used Proxmox API (pvesh) for direct migration:
VMIDs 100-130:
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
--target r630-01 \
--online 0
VMIDs 7800-7811:
pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
--target r630-01 \
--storage local \
--online 0
Storage Distribution
r630-01 Storage Usage
- thin1: VMIDs 100-130 (96 GB)
- local: VMIDs 7800-7811 (210 GB)
- Total Used: 306 GB
- Available: 638 GB remaining
Verification
Pre-Migration
- ✅ All VMs verified on r630-02
- ✅ Storage capacity confirmed sufficient
- ✅ Storage configuration fixed
Post-Migration
- ✅ All 12 VMs verified on r630-01
- ✅ No VMs remaining on r630-02 for these VMIDs
- ✅ Storage usage confirmed
Migration Timeline
- Storage Configuration Fix: Updated thin1 config and enabled storage
- VMIDs 100-130 Migration: Migrated to thin1 storage
- VMIDs 7800-7811 Migration: Migrated to local storage
- Verification: Confirmed all VMs on r630-01
Next Steps
- ✅ Verify VM functionality
- ✅ Monitor storage usage
- ✅ Update documentation
- ✅ Consider cleanup of old storage volumes (if needed)
Last Updated: 2025-01-20
Status: ✅ MIGRATION COMPLETE