Files
proxmox/reports/R630_01_MIGRATION_COMPLETE.md
defiQUG cb47cce074 Complete markdown files cleanup and organization
- Organized 252 files across project
- Root directory: 187 → 2 files (98.9% reduction)
- Moved configuration guides to docs/04-configuration/
- Moved troubleshooting guides to docs/09-troubleshooting/
- Moved quick start guides to docs/01-getting-started/
- Moved reports to reports/ directory
- Archived temporary files
- Generated comprehensive reports and documentation
- Created maintenance scripts and guides

All files organized according to established standards.
2026-01-06 01:46:25 -08:00

2.4 KiB

r630-01 Migration Complete - VMIDs 100-130 and 7800-7811

Date: 2025-01-20
Status: Migration Complete
Method: Direct migration via API after storage configuration fix


Migration Summary

VMs Migrated

VMIDs 100-130 (7 containers) → thin1 storage:

  • 100: proxmox-mail-gateway
  • 101: proxmox-datacenter-manager
  • 102: cloudflared
  • 103: omada
  • 104: gitea
  • 105: nginxproxymanager
  • 130: monitoring-1

VMIDs 7800-7811 (5 containers) → local storage:

  • 7800: sankofa-api-1
  • 7801: sankofa-portal-1
  • 7802: sankofa-keycloak-1
  • 7810: mim-web-1
  • 7811: mim-api-1

Total: 12 containers successfully migrated


Issues Resolved

Storage Configuration Fix

Problem:

  • thin1 storage configuration on r630-02 pointed to nodes r630-01
  • thin1 storage showed as disabled on r630-02
  • Migration and backup operations failed

Solution:

  1. Updated storage configuration: Changed nodes r630-01 to nodes r630-02 for thin1
  2. Enabled thin1 storage: pvesm set thin1 --disable 0
  3. Migration then succeeded using API method

Migration Method

Direct Migration via API

Used Proxmox API (pvesh) for direct migration:

VMIDs 100-130:

pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
    --target r630-01 \
    --online 0

VMIDs 7800-7811:

pvesh create /nodes/r630-02/lxc/<vmid>/migrate \
    --target r630-01 \
    --storage local \
    --online 0

Storage Distribution

r630-01 Storage Usage

  • thin1: VMIDs 100-130 (96 GB)
  • local: VMIDs 7800-7811 (210 GB)
  • Total Used: 306 GB
  • Available: 638 GB remaining

Verification

Pre-Migration

  • All VMs verified on r630-02
  • Storage capacity confirmed sufficient
  • Storage configuration fixed

Post-Migration

  • All 12 VMs verified on r630-01
  • No VMs remaining on r630-02 for these VMIDs
  • Storage usage confirmed

Migration Timeline

  1. Storage Configuration Fix: Updated thin1 config and enabled storage
  2. VMIDs 100-130 Migration: Migrated to thin1 storage
  3. VMIDs 7800-7811 Migration: Migrated to local storage
  4. Verification: Confirmed all VMs on r630-01

Next Steps

  1. Verify VM functionality
  2. Monitor storage usage
  3. Update documentation
  4. Consider cleanup of old storage volumes (if needed)

Last Updated: 2025-01-20
Status: MIGRATION COMPLETE